Straight secured IV catheter

Automatic safety: Reduced needlestick ABE (Accidental Blood Exposure). After removing the mandrin, the safety system locks on the needle bevel and is irreversible,
Ergonomics: No need to change technique, compact design, no risk of unintentional activation, very good reflux visualisation,
Biocompatibility: Polyurethane catheter,
Comfort: Fine needle that can be inserted into the vein without trauma,
Specific feature: Radiopaque catheter.

Informations
techniques

Indications 
Implementation of a peripheral catheter

Matériaux utilisés 
Polycarbonate: Mandrin base - Polypropylene: Sleeve of protector, filter, catheter base - Stainless steel: Protector, mandrin - Polyurethane PUR: Catheter - Polyoxymethylene POM: Seal.

Étiquetage 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

dispositif médical 

  • MD class : IIa
  • MD notified body : 0123
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : II

stérile 

  • stérile : yes
  • sterilization method : ethylene oxide

Straight secured IV catheter

Automatic safety: Reduced needlestick ABE (Accidental Blood Exposure). After removing the mandrin, the safety system locks on the needle bevel and is irreversible,
Ergonomics: No need to change technique, compact design, no risk of unintentional activation, very good reflux visualisation,
Biocompatibility: Polyurethane catheter,
Comfort: Fine needle that can be inserted into the vein without trauma,
Specific feature: Radiopaque catheter.

Indications 
Implementation of a peripheral catheter

Matériaux utilisés 
Polycarbonate: Mandrin base - Polypropylene: Sleeve of protector, filter, catheter base - Stainless steel: Protector, mandrin - Polyurethane PUR: Catheter - Polyoxymethylene POM: Seal.

Étiquetage 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

dispositif médical 

  • MD class : IIa
  • MD notified body : 0123
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : II

stérile 

  • stérile : yes
  • sterilization method : ethylene oxide

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.