ONCOLOGY RECONSTITUTION LINE PVC DEHP-FREE WITH BI-DIRECTIONAL VALVE SINGLE ACCESS MOBILE LUER LOCK

Reference : LR1VBDN

  • Reconstitution line with bidirectional valve
  • Air intake, mobile Luer Lock
  • Purge filter

Description

Reconstitution line:

Perforator: Two-channel with grip wings

Air intake: Delivered closed - 1.2μ filter,

Bidirectional valve:
Safe use: blending of drugs; asepsis maintained by automatic closing of the bidirectional valve following disconnection,

Safe assembly: The bidirectional valve, which is fastened during manufacturing, remains attached to the spike, preventing disassembly.
Tubing: DEHP-free PVC (DINCH) designed for flow adjustment Tubing diameter: 3 x 4.1mm
End cap: Mobile Luer Lock

Tube length: 25 cm
? End stopper: 0.8 μm purge filter with antibacterial membrane.

Technical
information

Indications 
This product is designed to blend cytostatic drugs in a closed system. The blended infusion bag is delivered to the administration unit equipped with this line; all you have to do is connect the mobile LL to one of the branches of the administration line. At the end of infusion, leave all bypasses connected and put them all into the circuit for eliminating contaminated devices in Oncology

Used materials 
PVC DINCH: Tubing - Acrylonitrile Butadiene Styrene: Perforator, mobile Luer Lock - Nylon: air intake - Polycarbonate: valve - Silicone: valve - Polyethylene: protective cap for perforator - POM: clamp

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 1370
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : V

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements

economic operator 

  • MANUFACTURER : DIDACTIC / 216 Rue Roland Moreno - 76210 Saint-Jean-de-

Logistics
information

Transport conditions 

Protected from light, humidity and heat

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 3661809024108
BOX 50 29 x 39 x 20 1.048 3661809124105
CASE 200 41 x 61 x 43 4.898 3661809224102

Reconstitution line:

Perforator: Two-channel with grip wings

Air intake: Delivered closed - 1.2μ filter,

Bidirectional valve:
Safe use: blending of drugs; asepsis maintained by automatic closing of the bidirectional valve following disconnection,

Safe assembly: The bidirectional valve, which is fastened during manufacturing, remains attached to the spike, preventing disassembly.
Tubing: DEHP-free PVC (DINCH) designed for flow adjustment Tubing diameter: 3 x 4.1mm
End cap: Mobile Luer Lock

Tube length: 25 cm
? End stopper: 0.8 μm purge filter with antibacterial membrane.

Indications 
This product is designed to blend cytostatic drugs in a closed system. The blended infusion bag is delivered to the administration unit equipped with this line; all you have to do is connect the mobile LL to one of the branches of the administration line. At the end of infusion, leave all bypasses connected and put them all into the circuit for eliminating contaminated devices in Oncology

Used materials 
PVC DINCH: Tubing - Acrylonitrile Butadiene Styrene: Perforator, mobile Luer Lock - Nylon: air intake - Polycarbonate: valve - Silicone: valve - Polyethylene: protective cap for perforator - POM: clamp

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 1370
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : V

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements

economic operator 

  • MANUFACTURER : DIDACTIC / 216 Rue Roland Moreno - 76210 Saint-Jean-de-

Transport conditions 

Protected from light, humidity and heat

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 3661809024108
BOX 50 29 x 39 x 20 1.048 3661809124105
CASE 200 41 x 61 x 43 4.898 3661809224102

Video(s)

Associated products

ONCOLOGY RECONSTITUTION LINE PVC PHOTOPROTECTOR DEHP-FREE WITH BI-DIRECTIONAL VALVE SINGLE ACCESS MOBILE LUER LOCK
ONCOLOGY RECONSTITUTION LINE PVC DEHP-FREE MOBILE LUER LOCK CONNECTOR

Associated products

ONCOLOGY RECONSTITUTION LINE PVC PHOTOPROTECTOR DEHP-FREE WITH BI-DIRECTIONAL VALVE SINGLE ACCESS MOBILE LUER LOCK
ONCOLOGY RECONSTITUTION LINE PVC DEHP-FREE MOBILE LUER LOCK CONNECTOR

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.