ADAPTOR VASCULAR LUER SAMPLING WITH PUMP HOUSING STERILE SINGLE USE SECURED PVC DEHP-FREE FOR MICROINFUSION SETS 30CM

Reference : MICPPR

  • Secured winged needle set (safety mechanism activated when needle is withdrawn) with sampling connector for attached pump body
  • 30-cm DEHP-free tubing
  • Gauge: 23G or 21G

Description

Safety: Prevents ABE (Accidental Blood Exposure) risk by needlestick. Secure device, which protects the tip of the needle as it is removed (see proper use sheet), Ergonomics: Easy insertion into the vein without risk of slipping; Comfort: Less pain compared to other sampling techniques, ease of use for the caregiver, Additional device: Non-sterile adaptable pump body, Leak test > 2960 hPa (2.96 bar/43 psi).

Technical
information

Indications 
Safe blood sampling

Used materials 
Polycarbonate: Needle protection system after use - Polyethylene: Protective cap for needle - Polypropylene: Protective cap for the female Luer and the needle, adaptable Luer central part, pump body - Stainless steel: Needle, cannula - PVC: Tubing, wings - Epoxy: Adhesive - Acrylonitrile Butadiene Styrene: Protective cap for the Luer connector, hub, shutoff system - Synthetic polyisoprene: rubber seal.

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 0123
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : II

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

Safety: Prevents ABE (Accidental Blood Exposure) risk by needlestick. Secure device, which protects the tip of the needle as it is removed (see proper use sheet), Ergonomics: Easy insertion into the vein without risk of slipping; Comfort: Less pain compared to other sampling techniques, ease of use for the caregiver, Additional device: Non-sterile adaptable pump body, Leak test > 2960 hPa (2.96 bar/43 psi).

Indications 
Safe blood sampling

Used materials 
Polycarbonate: Needle protection system after use - Polyethylene: Protective cap for needle - Polypropylene: Protective cap for the female Luer and the needle, adaptable Luer central part, pump body - Stainless steel: Needle, cannula - PVC: Tubing, wings - Epoxy: Adhesive - Acrylonitrile Butadiene Styrene: Protective cap for the Luer connector, hub, shutoff system - Synthetic polyisoprene: rubber seal.

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 0123
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : II

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.