You are:
The INFINEED lt;Gravity lt; 3-ways infusion set without DEHP, BPA-free was designed to minimize the environmental impact of the device. Two methods have been used: first, by reducing the plastic mass used by around 10%, without making any changes to functionality; second, by exclusively using raw materials that are free from endocrine disruptors (elimination of components comprising DEHP or BPA.)
The polycarbonate-free 3-way stopcock has been tested at pressures well above those recommended for gravity infusion; laboratory tests have shown a pressure resistance of approximately 10 bars.
Infuser with:
- Two-channel perforator.
- Air intake (0.2µm filter): Delivered closed for immediate use on an infusion bag.
- Chamber: Soft and translucent, the chamber is calibrated at 20 drops = 1ml ± 0.1ml. 15µm particle filter.
- Flow regulator: ABS linear flow control for good roller clamp rigidity, precision and reliability.
- BPA-free 3-way stopcock: Lipid-resistant with large valve stopcock and arrows indicating the direction of flow, permanently attached to the extension tube. Only the main line can be disconnected from the stopcock.
- Tubing: PVC (DINCH) designed for comfort, optimal flow adjustment consistency and to prevent kinks. Diameter: 3 x 4.1mm.
- End connector: Mobile Luer Lock.
- End cap with 0.8 µm purge filter (hydrophobic membrane) enabling automatic purging of the infusion line.
Length: 150cm + 30cm
Residual volume: 15.8 ml
Made in China.
Indications
This device allows the administration by gravity of injectable preparations by parenteral way: drugs, solutions, nutrition
For peripheral lines, the infusion line can remain in place for a maximum of 96 hours (i.e. the maximum time the peripheral catheter can be in place).
For central lines, the infusion line must be changed at least every 72 hours (or according to the institution's validated protocol).
Gravity infusion set, do not use for pressure infusion, transfusion or medicine that need a 0.2µm filter.
Dispose according to the state member regulation.
Used materials
PVC DINCH (DEHP <0.1%(m/m)): Chamber, air intake, Tubing - Polypropylene: tap cap - Polyethylene: tap key, HDPE: Protective cap for the perforator - Tritan® BPA free: Stopcock body - Acrylonitrile Butadiene Styrene: Perforator, regulator body, wheel, mobile Luer Lock - Polyamide: anti-particle filter at the bottom of the chamber - Polyethylene/PTFE: purge filter
Labeling
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable
medical device
sterile
conformity
economic operator
Transport conditions
Protect from light and humidity and store at a temperature between 5°C and 20°C.
Conditioning | Parts quantities | Dimensions in cm | Weight in kg | Ean 13 of conditioning |
UNIT | 1 | 10 x 25 x 1 | 0.029 | 3661809029356 |
BAG | 25 | 48 x 30 x 1 | 0.750 | 3661809129353 |
CASE | 250 | 58 x 40 x 25 | 9.100 | 3661809329357 |