WHITE MALE SHUTTER CAP

Référence : OBTMB02

  • Male shutter
  • White, sterile
  • Standardized luer lock connection

Description

Male shutter in white ABS.



Contact with 0.5% or 2% Chlorhexidine in 70° Isopropyl alcohol, without evaporation time, and while the luer lock is connected, therefore under physical stress, presents a significant risk of cracking of the luer lock, and should be avoided as much as possible.

In accordance with the recommendations of the SF2H (2019) and Didactic's disinfection protocol, it is always preferable to disinfect the connectors (when necessary) with 70° ethyl alcohol followed by a mandatory drying time of 15 secondes at least before connecting. 70° ethyl alcohol is just as effective disinfecting inert materials and then reduces the risk of altering plastic materials.

Made in China

Informations
techniques

Indications 
This device allows you to close a female Luer Lock tip. This device is used to protect infusers, syringes, etc. of contamination.

Matériaux utilisés 
STOPPER: in ABS.

Étiquetage 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

dispositif médical 

  • MD class : I
  • MD notified body : CE0197
  • EU directive/regulation : DIRECTIVE 93/42/CEE
  • annexe : V

stérile 

  • stérile : yes
  • sterilization method : ethylene oxide

conformité 

  • Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications

Informations
logistiques

Conditions de transport 

Protected from light and humidity

Conditionnement Quantités de pièces Dimensions en cm Poids en kg Ean 13 du conditionnement
UNIT 1 5 x 2 x 1 06972620110343
BOX 200 21 x 20 x 6 16972620110340
CASE 4000 45 x 42 x 32 26972620110347

Male shutter in white ABS.



Contact with 0.5% or 2% Chlorhexidine in 70° Isopropyl alcohol, without evaporation time, and while the luer lock is connected, therefore under physical stress, presents a significant risk of cracking of the luer lock, and should be avoided as much as possible.

In accordance with the recommendations of the SF2H (2019) and Didactic's disinfection protocol, it is always preferable to disinfect the connectors (when necessary) with 70° ethyl alcohol followed by a mandatory drying time of 15 secondes at least before connecting. 70° ethyl alcohol is just as effective disinfecting inert materials and then reduces the risk of altering plastic materials.

Made in China

Indications 
This device allows you to close a female Luer Lock tip. This device is used to protect infusers, syringes, etc. of contamination.

Matériaux utilisés 
STOPPER: in ABS.

Étiquetage 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

dispositif médical 

  • MD class : I
  • MD notified body : CE0197
  • EU directive/regulation : DIRECTIVE 93/42/CEE
  • annexe : V

stérile 

  • stérile : yes
  • sterilization method : ethylene oxide

conformité 

  • Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications

Conditions de transport 

Protected from light and humidity

Conditionnement Quantités de pièces Dimensions en cm Poids en kg Ean 13 du conditionnement
UNIT 1 5 x 2 x 1 06972620110343
BOX 200 21 x 20 x 6 16972620110340
CASE 4000 45 x 42 x 32 26972620110347

Produits associés

Produits associés

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.